May. 25, 2025
1.The Hall element deviates from the magnetic block and is placed in front of the magnetic block.
When the manual key is used to change the tool, the tool holder detects the tool holder
in-position signal as soon as it rotates, and then the tool holder is reversed immediately.
At this time, check whether the Hall element on the tool holder signal disk is deviated
from the position, and adjust the signal disk position so that the Hall element is aligned with the magnetic block.
2. The manual tool change key fails. At this time, the manual tool change key can be directly replaced.