Home > News

Pressure setting during indexing chuck use

Nov. 18, 2025

Different workpiece materials can withstand different pressures. 

The data in the table below are recommended pressures for several commonly used workpiece materials during indexing chuck use.


Noworkpiece materialClamping pressure
/MPa
Graduation pressure
/ MPa
1copper parts
aluminum parts
1.5-2.53-3.5
2Cast iron parts2.5-3.23.5-4
3steel parts
stainless steel parts
3-3.53.5-4

Notes:

1. The pressures listed above are recommended pressures. Adjustments can be made based on actual cutting and product deformation conditions during actual use.

2. The indexing pressure must be 0.5 MPa or higher than the clamping pressure, but should not exceed 4.5 MPa.

3. The chuck is designed for a maximum pressure of 5 MPa; actual use should not exceed 4.5 MPa.

4. For any other questions, please contact your Drake sales representative.